Evaluation of safety and efficacy of the TriPollar technology for the treatment of wrinkles
Steven D. Shapiro MD, Yoav Eros MD, Yoav Abrahami MD, Amos Leviav MD
https://doi.org/10.1002/lsm.22044
Conflict of Interest Disclosures: All authors have completed and submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest and none were reported.
Abstract
Introduction
Patient demand for non-surgical, non-invasive, and no-downtime wrinkle reduction treatment procedures has grown dramatically over the past decade as new treatments and technologies have been introduced. This study was performed in order to evaluate the safety and efficacy of the TriPollar radiofrequency (RF) technology and intended for wrinkle reduction treatment.
Methods
Thirty-seven Subjects were recruited in two sites and were treated for the reduction of facial wrinkles and rhytides and followed for 3 months after the last treatment. The safety of using the TriPollar system was established by the physicians' assessments and observations of adverse events after each treatment. To evaluate treatment efficacy, pre- and post-treatment photos were assessed using a blinded evaluation by two uninvolved physicians.
Results
No unexpected adverse side effects were detected or reported. All subjects participating in the study reported no pain or mild pain during the treatments. The photographic analysis of pre- and post-treatment by the two blinded physicians revealed improvement (downgrade of at least 1 score according to the Fitzpatrick scale) in 94% (according to first reviewer) and 97% (according to second reviewer) of study subjects. All patients (100%) were satisfied from treatment results to a different extent.
Conclusions
The results of this study clearly indicate that the TriPollar system offers a non-invasive, effective, safe and virtually painless wrinkle and rhytides reduction treatment. Lasers Surg. Med. 44: 453–458, 2012. © Wiley Periodicals, Inc.
REFERENCES
1 Gold MH. Tissue tightening: A hot topic utilizing deep dermal heating. J Drugs Dermatol 2007; 6: 1238–1242.
2 Alster TS, Lupton JR. Nonablative cutaneous remodeling using radiofrequency devices. Clin Dermatol 2007; 25: 487–491.
3 Sadick N, Sorhaindo L. The radiofrequency frontier: A review of radiofrequency and combined radiofrequency pulsed light technology in aesthetic medicine. Facial Plast Surg 2005; 21: 131–138.
4 Goldman P, Fitzpatrick E. Cutaneous laser surgery—The art and science of selective photothermolysis. Mosby Year Book (St. Louis). 1999; p 377.
5 Arnoczky SP, Aksan A. Thermal modification of connective tissues: Basic science considerations and clinical implications. J Am Acad Orthop Surg 2000; 8: 305–313.
6 Sadick NS, Makino Y. Selective electro-thermolysis in aesthetic medicine: A review. Lasers Surg Med 2004; 34: 91–97.
7 Kaplan H, Gat A. Clinical and histopathological results following TriPollar radiofrequency skin treatments. J Cosmet Laser Ther 2009; 11(2): 78–84.
8 Boisnic S, Branchet MC. Ex vivo human skin evaluation of localized fat reduction and anti-aging effect by TriPollar radio frequency treatments. J Cosmet Laser Ther 2010; 12(1): 25–31.
9 Levenberg A. Clinical experience with a TriPollar™ radiofrequency system for facial and body aesthetic treatments. Eur J Dermatol 2010; 20(5): 1–5.
10 Manuskiatti W, Wachirakaphan C, Lektrakul N, Varothai S. Circumference reduction and cellulite treatment with a TriPollar radiofrequency device: A pilot study. J Eur Acad Dermatol Venereol 2009; 23: 820–827.
11 Manuskiatti W, Boonthaweeyuwat E, Varothai S. Treatment of striae distensae with a TriPollar radiofrequency device: A pilot study. J Dermatolog Treat 2009; 20: 359–364.
12 Fitzpatrick RE, Goldman MP, Satur NM, Tope WD. Pulsed carbon dioxide laser resurfacing of photo-aged facial skin. Arch Dermatol 1996; 132: 395–402.
13 Fitzpatrick R, Geronemus R, Goldberg D, Kaminer M, Kilmer S, Ruiz-Esparza J. Multicenter study of noninvasive, radiofrequency for periorbital tissue tightening. Lasers Surg Med 2003; 33: 232–242.
14 Bassichis BA, Dayan S, Thomas JR. Use of nonablative radiofrequency device to rejuvenate the upper one-third of the face. Otolaryngol Head Neck Surg 2004; 130: 397–406.
15 Harth Y, Lischinsky D. A novel method for real-time skin impedance measurement during radiofrequency skin tightening treatments. J Cosmet Dermatol 2011; 10: 24–29.
16 De Felipe I, Del Cueto SR, Perez E, Redondo P. Adverse reactions after nonablative radiofrequency: follow-up of 290 patients. J Cosmet Dermatol 2007; 6: 163–166.